Error Code E CO
Communication Error — Main MICOM and Display MICOM
Moderate
Address soon - your appliance may not work properly
What This Means
Poor communication connection between Main PCB and Display PCB; Loose hinge wiring connection
How to Fix
- 1
Step 1: Check all connector hinge connections between Main PCB and Display PCB.
- 2
Step 2: Measure voltage at CON101 pins 18-16 — expected 12V; if absent, check hinge connection (loose) and if connection is good, replace Main PCB.
- 3
Step 3: Measure voltage at CON101 pins 10-16 — expected 5V; if absent, check hinge connection and if good, replace Main PCB.
- 4
Step 4: Measure voltage at CON101 pins 14-16 — expected NOT 0 or 5V; if 0 or 5V, replace Display PCB.
- 5
Step 5: Measure voltage at CON101 pins 12-16 — expected NOT 0 or 5V; if 0 or 5V, replace Main PCB.
- 6
Step 6: Measure voltage at CON5 pins 4-3 — expected NOT 0 or 5V; if 0 or 5V, replace Display PCB.
- 7
Step 7: Measure voltage at CON5 pins 5-3 — expected NOT 0 or 5V; if 0 or 5V, replace Main PCB.
- 8
Step 8: If all checks are normal, explain to customer.
This Error Applies To
LG LRFOC2606 Series Refrigerators (2023) (2023–present)
Related Error Codes
Flow Meter Defect / Lack of Water Supply
Refrigerator Sensor Error
Ice Room Sensor Error or Ice Maker Sensor Error
Room Temperature Sensor Error
Freezer Cubed Ice Maker Sensor Error
Ice Maker Kit Defect — Ice Maker Motor Malfunction
Freezer Sensor Error
Pantry / Icing Room Sensor Error